note modell des wohnbaus in einer stadt
note
note siehe Goodman: Study Notes in System Dynamics, Seite 332 ff
note
note Bevölkerungs-Sektor
note
L pop.k=pop.j+dt*(imr.jk-omr.jk-ndr.jk)
N pop=popi
C popi=30.3
note
note pop population (people)
note popi population initial value
note imr immigration rate (people/year)
note omr out-migration rate(people/year)
note
R imr.kl=nim*ammp.k*pop.k
C nim=.145
note
note nim normal immigration (fraction/year)
note ammp attractiveness for migration multiplier perceived (dimensionless)
note
A ammp.k=smooth(amm.k,mpt)
C mpt=5
note
note amm attractiveness for migration multiplier (dimensionless)
note mpt migrant perception time (years)
note
A amm.k=table(ammt,hr.k,0,2,.25)
T ammt=.05/.1/.2/.4/1/1.6/1.8/1.9/2
note
note ammt attractiveness for migration multiplier table
note hr housing ratio (dimensionless)
note
A dmm.k=1/amm.k
note
note dmm departure migration multiplier (dimensionless)
note
R omr.kl=nom*dmm.k*pop.k
C nom=.02
note
note nom normal out migration (fraction/year)
note
R ndr.kl=pop.k*drf
C drf=.025
note
note ndr net death rate (people/year)
note drf death rate factor (fraction/year)
note*************************************************************************
note housing sector
note*************************************************************************
note
L h.k=h.j+dt*(hcr.jk-hdr.jk)
N h=hi
c hi=10
note
note h housing (units)
note hcr housing construction rate (units/year)
note hdr housing demolition rate (units/year)
note hi initial value of houses (units)
note
R hcr.kl=nhc*hcm.k*lam.k*h.k
C nhc=.12
note
note nhc normal housing construction (fraction/year)
note hcm housing construction multiplier (dimensionless)
note lam land availability multiplier (dimensionless)
note
A hcm.k=table(hcmt,hr.k,0,2,.25)
T hcmt=2.5/2.4/2.3/2/1/.37/.2/.1/.05
note
A hr.k=h.k/hd.k
note
note hr housing ratio(dimensionless)
note hd housing desired (units)
note
A hd.k=pop.k*upp
C upp=.33
note
note upp units per person (unit/person)
note
A lam.k=table(lamt,lfo.k,0,1,.25)
T lamt=1/.8/.5/.2/0
note
note lfo land fraction occupied (dimensionless)
note
A lfo.k=H.k*lpu/land
C lpu=1
C land=1500
note
note lpu land per unit(acres/unit)
note land (acres)
note
R hdr.kl=h.k/alth
C alth=50
note
note alth average lifetime of housing (years)
note***********************************************************************
note control statements
note***********************************************************************
note
plot h=h(0,2000)/pop=p(0,8000)/hcr=c,hdr=d(0,100)
C dt=1
C length=200
C pltper=2
|